home *** CD-ROM | disk | FTP | other *** search
/ Linear Technology Linearview 1996 / linearview 1996.iso / spice / lt1220 < prev    next >
Encoding:
Text File  |  1996-07-09  |  4.0 KB  |  129 lines

  1. * Linear Technology LT1220 op amp model  
  2. * Written: 2-01-1993 15:24:16 Type: Bipolar NPN input, internal comp.
  3. * Modified by G.F. to add Cload compensation network and freq. shaping
  4. * Typical specs: 
  5. * Vos=5.0E-04, Ib=1.0E-07, Ios=1.0E-07, GBP=45E+06Hz, Phase mar.= 50 deg Av=1, 
  6. * SR(-)=250V/us, SR(+)=250V/us, Av= 94dB, CMRR=114dB, 
  7. * Vsat(+)=2.00V, Vsat(-)=2.50V, Isc=+40/-40mA, Rout=50ohms, Iq=8.00mA.
  8. * Connections: + - V+V-O 
  9. .SUBCKT LT1220 3 2 7 4 6 
  10. * INPUT
  11. RC1 7  80 1E+03
  12. RC2 7  90 1E+03
  13. Q1  80 2  10 QM1 
  14. Q2  90 3  11 QM2 
  15. CIN 2  3  2.0000E-12
  16. C1  80 90 0.265E-12
  17. *INPUT POLE AT 300MHZ
  18. RE1 10 12 848
  19. RE2 11 12 848
  20. IEE 12 4  1E-03
  21. RE  12 0  2.3E+05
  22. CE  12 0  .75E-12
  23. *CE ADDED TO GIVE ASSYMETRICAL SLEW FOR NON-INVERTING GAINS
  24. * INTERMEDIATE
  25. *MODS: GA DEPENDENCE INVERTED (POLARITY SWAPPED)
  26. *      R2 INCREASED TO 50MOHM (ALL GAIN IN ONE STAGE)
  27. *      C2 TIED TO GROUND (WAS NODE 1), REDUCED TO 3.11PF FROM 3.54PF 
  28. *      GB POLARITY REVERSED, GB=1/R02 FOR GAIN OF 1 
  29. *      RF, CF ADDED FOR CLOAD NETWORK (REDUCES VALUE OF C2)
  30. *      REVERSE POLARITY OF GNL,GPL,GCL,GCM FOR LIMITING BECAUSE OF GA REVERSAL
  31. *      ADD MULTIPLE POLES AND A ZERO BETWEEN GA STAGE AND GB STAGE
  32. GCM 8  0  12 0  1.8E-09
  33. GA  8  0  90 80 1.0E-3
  34. R2  8  0  47.7E+06
  35. C2  8  0  3.51E-12
  36. *POLE AT 180MHZ
  37. GX1 0  28 8  0  1E-06
  38. RX1 28 0  1E+06
  39. CX1 28 0  0.885E-15
  40. *POLE AT 180MHZ
  41. GX2 0  38 28 0  1E-06
  42. RX2 38 0  1E+06
  43. CX2 38 0  0.885E-15
  44. *POLE AT 240MHZ
  45. GX3 0  48 38 0  1E-06
  46. RX3 48 0  1E+06
  47. CX3 48 0  0.663E-15  
  48. *ZERO AT 60MHZ
  49. GX4 0  58 48 0  1E-06
  50. RX4 58 59 1E+06
  51. LX4 59 0  2.65E-03
  52. *POLE AT 360MHZ
  53. GX5 0  68 58 0  1E-06
  54. RX5 68 0 1E+06
  55. CX5 68 0 .443E-15
  56. *POLE AT 360MHZ
  57. GX6 0  78 68 0  1E-06
  58. RX6 78 0  1E+06
  59. CX6 78 0  .443E-15
  60. *
  61. GB  0  1  78 0  20.4E-03
  62. RO2 1  0  49
  63. RF  8  99 3200
  64. CF  99 6  5E-12
  65. * OUTPUT 
  66. RSO 1  6  1.0000E+00
  67. ECL 18 0  1  6  2.3987E+01
  68. GCL 8  0  20 0  1.0000E+00
  69. RCL 20 0  1.0000E+01
  70. D1  18 19 DM1  
  71. VOD1 19 20 5.9605E-08
  72. D2  20 21 DM1  
  73. VOD2 21 18 5.9605E-08
  74. D3A 131 70 DM3 
  75. D3B 13 131 DM3 
  76. GPL 8  0  70 7  1.0000E+00
  77. VC  13 6  3.4909E+00
  78. RPLA 7  70 1.0000E+01
  79. RPLB 7  131 1.0000E+03
  80. D4A 60 141 DM3 
  81. D4B 141 14  DM3 
  82. GNL 8  0  60 4  1.0000E+00
  83. VE  6  14 3.9909E+00
  84. RNLA 60 4  1.0000E+01
  85. RNLB 141 4  1.0000E+03
  86. IP  7  4  7E-03
  87. DSUB 4  7  DM2  
  88. * MODELS 
  89. .MODEL QM1 NPN (IS=8.0E-16 BF=10E+03)
  90. .MODEL QM2 NPN (IS=8.19E-16 BF=3.33E+03)
  91. .MODEL DM1  D   (IS=1.0000E-20)
  92. .MODEL DM2  D   (IS=8.0000E-16 BV=4.3200E+01)
  93. .MODEL DM3  D   (IS=1.0000E-16)
  94. .ENDS LT1220
  95. * - - - - - * FINI LT1220 * - - - - - *
  96. ***
  97. *         (C) COPYRIGHT LINEAR TECHNOLOGY CORPORATION 1993
  98. *                       All rights reserved.
  99. *   Linear Technology Corporation hereby grants the users of this
  100. * macromodel a non-exclusive, nontransferrable license to use this
  101. *            macromodel under the following conditions:
  102. * The user agrees that this macromodel is licensed from Linear
  103. * Technology and agrees that the macromodel may be used, loaned,
  104. * given away or included in other model libraries as long as this
  105. * notice and the model in its entirety and unchanged is included.
  106. * No right to make derivative works or modifications to the
  107. * macromodel is granted hereby.  All such rights are reserved.
  108. * This model is provided as is.  Linear Technology makes no
  109. * warranty, either expressed or implied about the suitability or
  110. * fitness of this model for any particular purpose.  In no event
  111. * will Linear Technology be liable for special, collateral,
  112. * incidental or consequential damages in connection with or arising
  113. * out of the use of this macromodel.  It should be remembered that
  114. * models are a simplification of the actual circuit.
  115. * Linear Technology reserves the right to change these macromodels
  116. * without prior notice.  Contact Linear Technology at 1630 McCarthy
  117. * Blvd., Milpitas, CA, 95035-7487 or telephone 408/432-1900 for
  118. * datasheets on the actual amplifiers or the latest macromodels.
  119. * ----------------------------------------------------------------------- *